Rockwell Automation 1732E-XXXX ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect User Manual
Page 13
1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 13
Publication 1732E-IN010C-EN-E - June 2013
Auxiliary Power Connector
The 1732E-12X4M12QCDR, 1732E-16CFGM12QCR, and
1732E-16CFGM12QCWR modules use 4-pin auxiliary power connections. Attach the
mini-style 4-pin connector to the mini-style 4-pin receptacle as shown below.
Mini-style 4-Pin Receptacle
The 1732E-12X4M12P5QCDR, 1732E-16CFGM12P5QCR, and
1732E-16CFGM12P5QCWR modules use 5-pin auxiliary power connections. Attach
the mini-style 5-pin connector to the mini-style 5-pin receptacle as shown below.
Mini-style 5-Pin Receptacle
TIP
The ground for both module power and output power are shared.
ATTENTION: This equipment is considered Group 1, Class A industrial
equipment according to IEC/CISPR 11. Without appropriate precautions, there
may be difficulties with electromagnetic compatibility in residential and other
environments due to conducted and radiated disturbance.
4
2
3
1
44809
(View into receptacle)
Pin 1
Output power+
Pin 2
Sensor/MDL power+
Pin 3
Sensor/MDL power-
Pin 4
Output power-
4
2
3
1
45677
Male Input
Female Output
4
2
5
1
3
46199
(View into receptacle)
Pin 1
Output power-
Pin 2
Sensor/MDL power-
Pin 3
Protective Earth
Pin 4
Sensor/MDL power+
Pin 5
Output power+
4
2
5
1
3
46200
Male Input
Female Output