Non exclusive – Rockwell Automation 20B PowerFlex 70, PowerFlex 700 Reference Manual User Manual
Page 126
Owners
126
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
Non Exclusive
Multiple adapters can simultaneously issue the same command and multiple bits
may be high.
Conversely, any number of adapters can simultaneously issue Stop Commands.
Therefore, Stop Ownership is not exclusive.
Example:
The operator presses the Stop button on the Local HIM to stop the drive. When
the operator attempts to restart the drive by pressing the HIM Start button, the
drive does not restart. The operator needs to determine why the drive will not
restart.
CO
M
M
UN
IC
A
T
IO
N
S
Masks
&
O
w
ners
288 [Stop Owner]
Adapters presently issuing a valid stop command.
Read Only
276
thru
285
289 [Start Owner]
Adapters that are presently issuing a valid start command.
See [Stop Owner]
276
thru
285
290 [Jog Owner]
Adapters that are presently issuing a valid jog
command.
See [Stop Owner]
276
thru
285
291 [Direction Owner]
Adapter that currently has exclusive control of direction
changes.
See [Stop Owner]
276
thru
285
292 [Reference Owner]
Adapter that has the exclusive control of the command
frequency source selection.
See [Stop Owner]
276
thru
285
293 [Accel Owner]
Adapter that has exclusive control of selecting [Accel
Time 1, 2].
See [Stop Owner]
140
276
thru
285
294 [Decel Owner]
Adapter that has exclusive control of selecting [Decel
Time 1, 2].
See [Stop Owner]
142
276
thru
285
295 [Fault Clr Owner]
Adapter that is presently clearing a fault.
See [Stop Owner]
276
thru
285
296 [MOP Owner]
Adapters that are currently issuing increases or
decreases in MOP command frequency.
See [Stop Owner]
276
thru
285
297 [Local Owner]
Adapter that has requested exclusive control of all drive
logic functions. If an adapter is in local lockout, all other
functions (except stop) on all other adapters are locked
out and non-functional. Local control can only be
obtained when the drive is not running.
See [Stop Owner]
276
thru
285
0
0
0
1
0
0
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Issuing Command
0
=No Command
x =Reserved
Bit #
Digital In
DPI P
or
t 1
DPI P
or
t 2
DPI P
or
t 3
DPI P
or
t 4
DPI P
or
t 5