Figure 18 set up for cable loss measurement – Bird Technologies SA-6000EX User Manual

Page 60

Advertising
background image

Bird Technologies

44

Figure 18 Set Up for Cable Loss Measurement

5. Select the Freq softkey and set the frequency start and stop to a

range that is well beyond the normal range of the antenna (refer

to Setting the Measurement Frequency, page 18).

Note:

For example, for a 450 MHz antenna, set the start

frequency at 400 and the stop frequency at 500 MHz, for an 800
MHz antenna, set the start frequency at 700 and the stop fre-
quency at 1,100 MHz.

6. Connect a phase stable cable to the Site Analyzer antenna test

port and connect a Cal Combo to the other end of the cable.

7. Calibrate the Site Analyzer (See Calibrate the Site Analyzer, page 21).

Note:

After calibration, with the load still connected, the

output must below -25 dB. If it is not, there is a problem.

8. Remove the Cal Combo unit from the cable. Do not disconnect the

phase stable cable from the Site Analyzer.

Step

Action

1

Press the Config key

2

Press the Scale softkey

3

Press the right or left scroll keys to select Units

4

Press the up key to open the units list

5

Press the up or down keys to select Cbl Loss
and press Enter

Advertising