Operating instructions – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 42

Advertising
background image

40

P/N 68413 rev. A

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

Operating Instructions

Operating

Mode

Required

Event

Reset

Indicator

Status

Indicator

Beam Status

Indicator

Diagnostic Display

OSSD

Outputs

Power-up

Apply Power

OFF

Single-Flash
Red

Single-Flash 
Red

Scan code flash 3x
(C1 or C2)

OFF

Alignment Mode –
Beam Blocked

Passes Internal
Tests

OFF

OFF

Red

OFF

OFF

Alignment Mode –
Beam Clear

Align Beam

Double-

Flash

OFF

Green

(1)

OFF

OFF

Run Mode –
Clear

Perform Reset

ON

Green

Green

(1)

“L”

ON

Latched
– Blocked

Beam Blocked

ON

Red

Red

“L”

OFF

Latched – Clear

Clear Beam

Flashing

Red

Green

(1)

“L”

OFF

Lockout Mode

Internal/External 
Fault

OFF

Flashing Red

OFF

Displays Error Code

*

Operating

Mode

Required

Event

Reset

Indicator

Status

Indicator

Beam Status

Indicator

Diagnostic Display

OSSD

Outputs

Power-up

Apply Power

OFF

Single-Flash
Red

Single-Flash 
Red

Scan code flash 3x
(C1 or C2)

OFF

Alignment Mode –
Beam Blocked

Passes Internal
Tests

OFF

OFF

Red

OFF

OFF

Run Mode –
Clear

Align Beam

ON

Green

Green

(1)

Dash

ON

Run Mode –
Blocked

Beam Blocked

ON

Red

Red

Dash

OFF

Run Mode –
Blocked

Internal/External 
Fault

OFF

Flashing Red

OFF

Displays Error Code

*

OFF

Receiver:  A bi-color red/green Beam Status indicator shows 

whether the beam is aligned and clear with a strong signal, 

clear but with a weak signal, or is blocked and/or misaligned. A 

yellow Reset indicator shows when the System is in Run mode 

or is waiting for a reset. A bi-color red/green Status indicator 

shows when the OSSD outputs are ON (green) or OFF (red), 

or the System is in lockout mode (flashing red). A 7-segment 

diagnostic display indicates the receiver’s Trip (–) or Latch (L) 

output configuration setting and displays a specific error code

when the receiver is in lockout. The 7-segment display also 

momentarily indicates the scan code setting at power-up or 

when changed. 

Figure 4-3a. Receiver status indicators and operation (Trip Output mode)

Figure 4-3b. Receiver status indicators and operation (Latch Output mode)

* See Section 5 .1 for a description of error codes

(1)

Flashing Green indicates a clear but weak signal.

* See Section 5 .1 for a description of error codes

(1)

Flashing Green indicates a clear but weak signal.

Advertising