4 salt use table – Watts Autotrol Magnum (CV+ Series) User Manual

Page 30

Advertising
background image

26

5.2.4 Salt Use Table

Notes:

1. Flow rates for refill controls are based on 60 psig (414 kPa) inlet pressure.

2. Take into account the type of brine system used when determining the actual amount of salt delivered during

regeneration. (i.e. dry salt/grid plate or wet salt)

3. Salt Use Table reflects minimum salting of 6 lbs./cu.ft. (96.11 kg/m

3

) through maximum salting of 15 lbs./cu.ft.

(240.27 kg/m

3

).

4. To use potassium chloride (KCl) increase salt dosage by approximately 25%.

5. Chloride/Anion dealkalizers regenerate with 5 lbs./cu.ft. (80.09 kg/m

3

) salt (NaCl) which yields approx. 7500 gr/

cu. ft. Injecting sodium hydroxide (NaOH) i.e. caustic soda, at a rate of 1/10 that of the salt dosage, during the
brine draw cycle, increases capacity to approx. 10000 gr./cu. ft. Exact capacity, based on tank size, must be
calculated using water analysis and resin manufacturer’s capacity curves.

Table 5.8 Model 942, 952, 952QC - Salt Used per Regeneration

Tank Size/Dia.

inches (cm)

14 (35.5)

16 (40.6)

18 (45.7)

21 (53.3)

24 ( 60.9)

30 (76.2)

36 (91.4)

Resin Volume

cu. ft. (cu. m.)

3 (0.85)

4 (0.113)

5 (0.142)

7 (0.200)

10

(0.283)

15

(0.425)

20

(0.566)

Refill Flow

Rate

GPM (LPM)

0.7 (2.65)

0.8 (3.03)

1.0 (3.78)

1.4 (5.30)

2.0 (7.57)

3.0

(11.36)

5.0

(18.93)

Salt Dial

Setting

(Minutes)

Approximate Pounds of Salt per Regeneration

8

18

--

--

--

--

--

120

10

21

24

30

42

60

90

150

12

25

29

36

50

72

108

180

14

29

34

42

59

84

126

210

16

34

38

48

67

96

144

240

18

38

43

54

76

108

162

270

20

42

48

60

84

120

180

300

22

45

53

66

92

132

198

--

24

--

60

75

105

150

225

--

Advertising