59

10.4 Drain Line Flow Control

*60

o

F (15

o

C) water temperature, 50% bed expansion

Table 10.3 Recommended Backwash Flow Rates for Various Media

Media

Tank Diameter

14 in

(35.6 cm)

Tank

16 in

(40.6 cm)

Tank

18 in

(45.7 cm)

Tank

21 in

(53.3 cm)

Tank

24 in

(61.0 cm)

Tank

30 in

(76.2 cm)

Tank

36 in

(91.4 cm)

Tank

Cubic Feet of Media/Drain Line Flow Control in GPM

*Softening Resin
(4.5 gpm/ft

2

)

(1.1 Lph/cm

2

)

3/5

4/6

5/8

7/12

10/15

15/25

20/30

*Fine Mesh
Softening Resin
(3.4 gpm/ft

2

)

(.83 Lph/cm

2

)

3/4

4/5

5/6

7/8

10/10

15/17

20/15

Multi Layer
(15 gpm/ft

2

)

(3.66 Lph/cm

2

)

3/15

4/20

5/25

6/30

7/50

10/70

15/105

Birm,
Greensand,
Carbon
(10 gpm/ft

2

)

(2.44 Lph/cm

2

)

3/10

4/15

5/17

7/20

10/30

15/50

20/70