Prefix 80 series exit device, Operating instructions – SARGENT 57 - Delayed Egress User Manual
Page 18
Armed Mode (Delayed Egress)
Green LED
Red LED
Momentary Egress Mode
Operating Instructions
There are three modes of operation: Armed (Delayed Egress), Momentary Egress and Maintained Egress.
1. Apply power to the System; horn will sound for one second
2. Both LEDs will flash RED, then both LEDs will flash GREEN
3. Green (default) or Red LED on Electroguard™ insert will illuminate
(See DIP switch settings section 7)
4. Rail assembly is armed. Latchbolt cannot be retracted by de-
pressing the push rail for immediate egress. If rail is depressed for
(min.) one second, alarm will sound.
5. If any of above sequence fails to function, the unit is not armed.
See: Troubleshooting section
1. Rotate key counter-clockwise to
2nd click and return key to
center position (key out)
2. Red (Default) or Green LED flashes on insert for a factory preset
time of 5 seconds. (For other time selections and LED color, see
Dip Switch Settings section 7.) The rail assembly will disarm itself
and de-energize the external magnet for this time period allowing
for momentary egress.
3. After the factory preset time of 5 seconds, delay expires. Rail
assembly re-arms itself and the external magnet is re-energized.
4. Unit is then in Delayed Egress Mode (or Power Up State)
*Depends on handing
10
These modes are set by fully inserting a valid key and rotating it in either a clockwise or counter-clockwise
direction until there is a click (detent).
Note that a second click must be engaged in order to set momentary egress.
To remove the key, it must be returned to its original center position.
Center (key out)
Maintained (Disarmed)
Delayed Egress (Armed)
1
st
click
Momentary Egress
2
nd
click
• Both insert LEDs illuminate "red" for 2 seconds while concurrently sounding buzzer for 500ms.
• Both insert LEDs illuminate "green" for 2 seconds (no buzzer)
• The (4) diagnostic LEDS on bottom of module illuminate for 2 seconds.
• Insert LED illuminates to the switch position (armed or not armed).
Note: Power-up sequence is as follows:
18 1-800-810-WIRE • www.sargentlock.com • A7743C
Copyright © 2013, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
04/15/13
57- Prefix 80 Series Exit Device
- FM8700 Surface Vertical Rod Exit Device PR8700 Center & Top Latch Surface Vertical Rods for Pair of Doors PP8700 Center & Top Latch Surface Vertical Rods for Pair of Doors HC8700 Hurricane Code Surface Vertical Rod Exit Device NB8700 Top Latch Surface Vertical Rod 8700 Surface Vertical Rod Exit Device SP8600 Center & Top Latch Concealed Vertical Rods PR8600 Center & Top Latch Concealed Vertical Rods PP8600 Center & Top Latch Concealed Vertical Rods LR8600 Low Profile Center & Top Latch Concealed Vertical Rod Exit Devices LP8600 Low Profile Center & Top Latch Concealed Vertical Rod Exit Devices NB-WD8600 Concealed Vertical Rod Exit Device for Wood Doors WD8600 Concealed Vertical Rod Exit Device for Wood Doors NB-MD8600 Concealed Vertical Rod Exit Device for Metal Doors MD8600 Concealed Vertical Rod Exit Device for Metal Doors NB-MD8400 Series Narrow Style Concealed Vertical Rod MD8400 Series Narrow Style Concealed Vertical Rod LS8600 Low Profile Center & Top Latch Concealed Vertical Rods WS8900 Mortise Lock 8900 Mortise Lock Exit Device 8300 8888 Reversible Rim Exit Device 8800 Rim Exit Device 8500 Narrow Design Rim Exit Device HC8800 Rim Exit Device