Salter Brecknell WB-521 Series User Manual

Page 45

Advertising
background image

SBI521 Service Manual

43

*The setting will be limited by the choice of REGULA

FILTER

FLT1.TH 0-255

40

Digital filter1 threshold:

0=no filter1
1-254=filter1 used only when
vibration in ±0.5d*(1-254)
255= filter1 be always used

FLT1.ST

1-64

8

Digital filter1 intensity

1-64 ADC’s data will be averaged

FLT2.TH

0-255

8

Digital filter2 threshold

0=no filter2
1-254=filter2 used only when
vibration in ±0.25d*(1-254)
255= filter2 be always used

FLT2.ST

0-255

240

Digital filter2 intensity

0-255=weak to strong

FUNC

HOLD

YES

YES

Enable or disable hold
function

YES
NO

NO

COUNT

YES

NO

Enable or disable
counting function

YES
NO

NO

PERCNT

NO

NO

Enable or disable percent
weighing function

(1)NO=disable
(2)100%=enable and display format
is 100%
(3)100.0%=enable and display
format is 100.0%
(4)100.00%=enable and display
format is 100.00%

100%

100.0%

100.00%

COMPAR

YES

YES

Enable or disable data
comparison function

YES
NO

NO

ACCUMU

NO

NO

Accumulation Mode
selection

(1)NO=no accumulation function
(2)MANUAL=add up current number
to accumulation memory after
[TOTAL] key is pressed
(3)AUTO=automatically add up
current number to accumulation
memory after scale is stable and
weight is over (NLD.RNG)

MANUAL

AUTO

WT.ADJ

YES

NO

Enable or disable weight
fine-tuning using keypad
in weighing mode

YES
NO
*If (REGULA) ≠none, this item is
NO

CONFIG

SubMenu1

SubMenu2

Option

Default

Parameter Description

Comment

Advertising