1038 series, Ul specifications, Installation instructions – Interlogix 1038 Series User Manual

Page 2: Surface mount with wire leads, Ge interlogix

Advertising
background image

UL Specifications

Part

Loop

Electrical

Gap

Number

Type

Configuration

Distance

*

1038

Closed

N.O.

1"

*

Gap Specifications are nominal and may vary

±

20%. Gap Specifications are for switch to make.

Break distance is approximately 1.1 to 1.5 times make.

WARNING: Each electrical rating is an individual maximum and cannot be exceeded!

**

FORM A (1038)
Voltage: 100 V AC/DC max
Current: 0.5 A max
Power: 7.5 W max

1038 Series

Surface Mount with Wire Leads

Installation Instructions

1. Clean mounting surfaces with alcohol pad (included).

2. Align and attach mounting plates for the switch and magnet using tape or screws (included).

Wire may be routed on either end or through the top of the switch housing cutouts.

3. Strip loop wire and connect the leads to the alarm loop.

4. Place switch and magnet covers over the center of the mounting plates and slide either left or

right until the cover snaps in place.

1038696 Rev A 07/02

www.GE-InterlogixSecurity.com