PRG Controlling VARI-LITE Equipment Using DMX 512 User Manual

Page 118

Advertising
background image

DMX512 R

EFERENCE

G

UIDE

1 1 0

02.3004.0300.54

6

Plate cycles full travel (75%)

along Y vector

5

Plate cycles full travel (100%)

along Y vector

4

Plate cycles full travel (25%)

along X vector

3

Plate cycles full travel (50%)

along X vector

2

Plate cycles full travel (75%)

along X vector

1

Plate cycles full travel (100%)

along X vector

0

Plate moves from X & Y EOT

to opposite X & Y EOT syn-

chronous repeatedly (100%)

008

Fixed Gobo

N/A

009

Rotating Gobos

9

Cycle from wheel position 0
to position 1 CW, from posi-

tion 1 to position 0 CCW

repeatedly. Pause briefly on

position 0 and 1

8

Cycle from wheel position 0

to position 5 CCW, from posi-

tion 5 to position 0 CW

repeatedly. Pause briefly on

position 0 and 5

7

Cycle from wheel position 0
to position 3 CW, from posi-

tion 3 to position 0 CCW

repeatedly. Pause briefly on

position 0 and 3

6

Cycle from wheel position 0

to position to position 6 CCW,

from position 6 to position 0

CCW repeatedly. Pause

briefly on position 0 and 6

5

Continuous wheel position

CW to next gobo position on

wheel (from 2 to 3, 5 to 0)

Gobos on wheels do not

rotate. Pause briefly on each

gobo

4

Cycle gobos between orien-

tation 0° & 180°

3

Spin gobos CW (100%)

wheel does not move

2

Spin gobos CW (50%) wheel

does not move

Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)