1 1 0
02.3004.0300.54
6
Plate cycles full travel (75%)
along Y vector
5
Plate cycles full travel (100%)
along Y vector
4
Plate cycles full travel (25%)
along X vector
3
Plate cycles full travel (50%)
along X vector
2
Plate cycles full travel (75%)
along X vector
1
Plate cycles full travel (100%)
along X vector
0
Plate moves from X & Y EOT
to opposite X & Y EOT syn-
chronous repeatedly (100%)
008
Fixed Gobo
N/A
009
Rotating Gobos
9
Cycle from wheel position 0
to position 1 CW, from posi-
tion 1 to position 0 CCW
repeatedly. Pause briefly on
position 0 and 1
8
Cycle from wheel position 0
to position 5 CCW, from posi-
tion 5 to position 0 CW
repeatedly. Pause briefly on
position 0 and 5
7
Cycle from wheel position 0
to position 3 CW, from posi-
tion 3 to position 0 CCW
repeatedly. Pause briefly on
position 0 and 3
6
Cycle from wheel position 0
to position to position 6 CCW,
from position 6 to position 0
CCW repeatedly. Pause
briefly on position 0 and 6
5
Continuous wheel position
CW to next gobo position on
wheel (from 2 to 3, 5 to 0)
Gobos on wheels do not
rotate. Pause briefly on each
gobo
4
Cycle gobos between orien-
tation 0° & 180°
3
Spin gobos CW (100%)
wheel does not move
2
Spin gobos CW (50%) wheel
does not move
Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)
Test Number
Test Parameter
Error Codes/Comments