TYPICAL WIRING DIAGRAMS

For wiring diagrams of ballasts not shown, consult our Customer Service.

11. ONE LAMP RAPID START BALLAST

13. TWO LAMP RAPID START BALLAST WITH TWO LAMP OPERATION

12. TWO LAMP RAPID START BALLAST

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

SWITCHED OR

UNSWITCHED LINE

BLACK

WHITE

BLUE

BLUE

RED
RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

ONE LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

VIOLET

BROWN

BRN/WHT

1CFL_460

LAMP

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

SWITCHED OR

UNSWITCHED LINE

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

TWO LAMP RAPID START BALLAST WITH TWO LAMP OPERATION

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

VIOLET

BROWN

BRN/WHT

2CFL_2LEO_460

*LAMP

*LAMP

UNSWITCHED

ORG (277V)
BLK (120V)

WHT/BLK

5

COMMON

WHITE

SWITCHED OR

UNSWITCHED LINE

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED
RED

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

TWO LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

SELECT PROPER VOLTAGE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRING ON ILLUSTRATION 3

OF INSTALLATION MANUAL FOR PROPER

INPUT CIRCUIT WIRING.
DO NOT MATE CONNECTOR UNTIL

INSTALLATION IS COMPLETE AND

AC POWER IS SUPPLIED.

LAMP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORY LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITY WIRING.

5

USE EITHER WHT/BLK LEAD

FOR WIRING THE COMMON.

REFER TO AC INPUT WIRING

ON ILLUSTRATION 3 OF

INSTALLATION MANUAL.

VIOLET

BROWN

BRN/WHT

2CFL_460

*LAMP

LAMP

I-160

ChARgE

INDICATOR

I-160

ChARgE

INDICATOR

I-160

ChARgE

INDICATOR

Insert

rev 1400
68160-102

SELECT PROPER VOLTAgE

LEAD. CAP UNUSED LEAD. REFER TO

AC INPUT WIRINg ON ILLUSTRATION 3

OF INSTALLATION mANUAL FOR PROPER

INPUT CIRCUIT WIRINg.
DO NOT mATE CONNECTOR UNTIL

INSTALLATION IS COmPLETE AND

AC POWER IS SUPPLIED.

LAmP SELECTOR LEADS—REFER

TO INSTALLATION INSTRUCTIONS,

LAmPS OPERATION SECTION FOR

VARIOUS OPTIONS
TEST ACCESSORy LEADS-

REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER

POLARITy WIRINg.

5

USE EIThER WhT/BLK LEAD

FOR WIRINg ThE COmmON.

REFER TO AC INPUT WIRINg

ON ILLUSTRATION 3 OF

INSTALLATION mANUAL.
CONNECT BLU/WhT AND

RED/WhT WIRES TOgEThER

6

Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf