PT-Basic Programming Manual Ver. 1.00

32/143

OFF TIMER

Purpose: To terminate TIMER event trigger.

Syntax: OFF TIMER(N%)

Example: ON TIMER(1,200) GOSUB A1

ON TIMER(2,300) GOSUB A2

A1:

OFF TIMER(1)

RETURN

A2:

OFF TIMER(2)

RETURN

Description: To resume the event trigger, call ON TIMER… GOSUB…

N% is an integer variable in the range of 1 to 5, indicating the

timer ID.

ON COM GOSUB

Purpose: To activate COM event trigger.

Syntax: ON COM(N%) GOSUB SubLabel | SubName

Example: ON COM(1) GOSUB READ1

READ1:

OFF COM(1)

ON COM(1) GOSUB READ1

RETURN

Description: When data is received from the COM port, a specific

subroutine will be executed.

N% is an integer variable, indicating the COM port (now we

only can choose 1).

Advertising