3.8 Beeper commands

BEEP

Purpose: To assign a beeper sequence to designate beeper operation.

Syntax: BEEP(freq%, duration% {, freq%, duration%})

Example: BEEP(99,30,0,10,88,30,0,10,66,30,0,0)

Description: freq% is an integer variable, indicating the value of Beep

frequency ( 76000 / Actual Frequency Desired ).

A beep frequency is an integer used to specify the frequency

(tone) when the beeper been activated. The actual frequency

that the beeper gives is not the value specified to the beep

frequency. It is calculated by the following formula.

For instance, to get a frequency of 2000Hz, the value of beep

frequency should be 38. If no sound is desired (pause), the

beep frequency should be set to 0. A beep with frequency 0

does not terminate the beeper sequence. Suitable frequency for

the beeper ranges from 1 to 2700Hz, while peak volume is at

around 2000Hz.

Duration% is an integer variable, indicating the value of

beeping duration, which is specified in units of 10 ms.

STOP BEEP

Purpose: To terminate beeper sequence.

Syntax: STOP BEEP

Example: BEEP(99,100,0,30,88,100,66,100,0,0)

WAIT(200)

STOP BEEP

Description: The STOP BEEP statement terminates the beeping

immediately if there is a beeper sequence in progress.