Purpose: To activate READER event trigger.
Syntax: ON READER(N%) GOSUB SubLabel | SubName
Example: ON READER(1) GOSUB GetData
…
GetData:
OFF READER(1)
CLS
A$=GET_READER_DATA$(1,4)
PRINT "DATA:"+A$
LOCATE 0,2
A$=GET_READER_DATA$(1,1)
PRINT "Name:"+A$
LOCATE 0,4
PRINT GET_READER_DATALEN
…
ON READER(1) GOSUB GetData
RETURN
Description: When data is received from reader port, a specific subroutine
will be executed.