o Zone Fault LEDs on front panel of IDA8C/S.
Log
o Amplifier Gain Too High
Text messages display at touch screen on front panel of IDA8C:
"Normal AMP Error", where Normal AMP can be Backup AMP.
"Z1 Normal AMP Too High", where Z1 can be any zone, Normal AMP can be Backup
AMP.
Text message display at window [Machine Fault Record] of Ateis Studio:
o Amplifier Gain Too Low
Text messages display at touch screen on front panel of IDA8C:
"Normal AMP Error", where Normal AMP can be Backup AMP.
"Z1 Normal AMP Too Low", where Z1 can be any zone, Normal AMP can be Backup
AMP.
Text message display at window [Machine Fault Record] of Ateis Studio:
o Amplifier Fail
Text messages display at touch screen on front panel of IDA8C:
"Normal AMP Error", where Normal AMP can be Backup AMP.
"Z1 Normal AMP Fail", where Z1 can be any zone, Normal AMP can be Backup AMP.
Text message display at window [Machine Fault Record] of Ateis Studio:
Buzzer sound output to monitoring speaker on front panel of IDA8C.