7 block up converter (buc) configuration – Comtech EF Data CDM-570 User Manual
Page 317
CDM-570/570L Satellite Modem with Optional IP Module
Revision 12
Ethernet IP Module - CLI and Telnet Operation
MN/CDM570L.IOM
14–47
14.2.9.7
Block Up Converter (BUC) Configuration
Activate the Block Up Converter (BUC) Configuration page from the Configuration page.
Figure 14-32. Block Up Converter (BUC) Configuration Page
The Block Up Converter (BUC) Configuration page contains the following options/fields:
Selection
Entry Description
BUC Address
A
Select a value from 1 to 15
BUC RF Output
R
Select as Enabled or Disabled.
BUC DC Power
W
BUC 10 MHz Reference
P
BUC Current Alarm Upper
Limit (mA)
H
Enter a value from 500 to 4000
BUC Current Alarm Lower
Limit (mA)
C
Enter a value from 0 to 3000
BUC LO Frequency (MHz)
F
Enter a value from 3000 to 65000, 0 to disable