D.5 packet structure, D.5.1 start of packet, D.5.2 target address – Comtech EF Data CDM-570 User Manual

Page 353

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–3

D.5

Packet Structure

Controller-to-Target

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional Arguments

End of Packet

<

ASCII code 60


(1 character)


(4 characters)

/

ASCII code 47


(1 character)


(3 characters)

= or ?

ASCII codes 61 or 63


(1 character)


(n characters)

Carriage Return

ASCII code 13


(1 character)

Example: <0135/TFQ=1949.2345{CR}

Target-to-Controller

Start of Packet

Target Address

Address Delimiter

Instruction Code

Code Qualifier

Optional Arguments

End of Packet

>

ASCII code 62

(1 character)

(4 characters)

/

ASCII code 47

(1 character)

(3 characters)

=, ?, !, or *

ASCII codes

61, 63, 33, or 42

(1 character)

(From 0 to n

characters)

Carriage Return, Line

Feed

ASCII codes 13,10

(2 characters)

Example: >0654/RSW=32{CR}{LF}

D.5.1 Start of Packet

Controller-to-Target: This is the character ‘<’ (ASCII code 60).

Target-to-Controller: This is the character ‘>’ (ASCII code 62).

Because this is used to provide a reliable indication of the start of packet, these two characters may not appear anywhere else within the
body of the message.

D.5.2 Target Address

Up to 9999 devices can be uniquely addressed. In EIA-232 applications this value is set to 0. In EIA-485 applications, the permissible
range of values is 1 to 9999. It is programmed into a Target unit using the front panel keypad.