Corn-1, Barley-2, Ing-01 – Digi-Star EZ 3200/EZ 3200V/EZ 3200V RC User Manual
Page 33
![background image](/files/781519/content/doc033.png)
Digi-Star Model EZ3200/EZ3200V/EZ3200V RC
6. System operation
30
! copyright - 10/24/2001
Method 2
1. Use the numeric keypad to enter the
ingredient number.
2. Press
. The ingredient name will be
displayed:
CORN-1
.
3. Press
to backspace or press & hold the
[Clear] key to delete the entire name.
4. Use the alpha-numeric keypad to enter the six
character/number ingredient name.
5. Press
to store the new name and advance
to the next ingredient.
!
To cancel your changes and restore the
original name, simply press
.
!""
A blank name " _" cannot be saved, instead the original name will be restored.
The ingredient names are saved into non-volatile memory. Non-volatile memory is a special type
of memory that allows the power to be removed from the scale without losing any of the
ingredient names.
6. Continue steps 2 through 5 until the desired changes have been made.
7. Press
to exit the Ingredient programming mode and enter the weighing modes
TO ERASE ACCUMULATION FOR
ONE INGREDIENT
1. Enter Ingredient Program Mode by pressing
and holding
and then pressing
.
2. Continue holding both keys until the indicator
beeps and the scale displays the message
PROGRM.
3. The scale then displays the first ingredient
number in the table
ING-01
. Use one of the
following methods to select the ingredient
name to erase:
Method 1
1. Press
until the desired ingredient number
is displayed. Go to step 4 of method 2 below.
corn-1
2
3
1
1
5
barley-2
4
4
7
ING-01
2