85 a shielded cutting (mild steel), 85 a shielded cutting (mild steel) -22, Powermax – Hypertherm Powermax105 Service Manual User Manual
Page 94
Machine Torch SeTup
6-22
powermax
105
Service Manual
85 A Shielded cutting (Mild Steel)
Air flow rate – slpm/scfh
Hot
194 / 412
Cold
236 / 500
Metric
Material
thickness
torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
time
best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
3
1.5
3.8
250
0.1
6800
122
9200
120
4
0.2
5650
122
7300
122
6
0.5
3600
123
4400
125
8
2500
125
3100
127
10
1680
127
2070
128
12
4.5
300
0.7
1280
130
1600
130
16
1.0
870
134
930
133
20
6.0
400
1.5
570
137
680
136
25
Edge Start
350
142
450
141
30
200
146
300
144
English
Material
thickness
torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
time
best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
inches
inches
inches
%
seconds
ipm
Volts
ipm
Volts
10GA
0.06
0.15
250
0.0
250
122
336
121
3/16
0.2
185
123
220
123
1/4
0.5
130
123
160
126
3/8
70
126
86
127
1/2
0.18
300
45
131
56
131
5/8
1.0
35
134
37
133
3/4
0.24
400
1.5
24
136
29
135
7/8
Edge Start
19
139
22
138
1
13
142
17
141
1-1/8
9
145
13
143
1-1/4
7
148
10
146