Operation Section

40

5.18 Compressor

(1) Compressor motor

• The CM 25 uses an inverter-controlled DC

compressor. The compressor motor is

operated by three-phase voltage outputted

from the STI module on the relay board.

Specifications:

- Rated Voltage: DC 220 V

- Rated Output: 1380 W

(2) Compressor overload relay

• An external compressor overload relay is used

to protect the compressor motor. This relay is

mounted within the connector housing that

attaches to the top of the compressor. The

relay interrupts high temperature build-up in

the compressor.

Specifications:

Temperature

Contact Open

248°F (120°C)

Contact Close

203°F (95°C)

I003143

I001691

Bimetal

Terminal

Points

Advertising