Condensing unit electrical – Scotsman EH330 C with ECC Condensing Unit ECC1200 User Manual

Page 16

Advertising
background image

EH330, EH430 and ECC Condensing Unit

Remote Low Side Cuber Service Manual

July 2013

Page 15

Condensing Unit Electrical

Route interconnecting control wire through proper

hole in side of CU unit and plug into the connection on

the side of the control box.

Route power conduit (liquid tight) and wires to the

hole in the side of the CU unit. Connect to wire leads

or terminal strip, if used, with the proper type of

connector.

Note: The power supply wires must be the correct

size and type per the National Electric Code.

Locate the nameplate on the CU unit for the Voltage,

Phase, Minimum Circuit Ampacity and Maximum Fuse

Size. Either fuses or HACR type circuit breakers may

be used.

Follow all Local, State and National Codes.

Three Phase Notice: Check voltage between legs

at contactor. If there is a “wild leg” in the three phase

power supply move supply wires so the higher voltage

is on L3 of the contactor, which connects to the

compressor motor only.