Control Safeties

Max freeze time – 45 minutes

When exceeded, the controller will attempt another

freeze cycle. If the condition is exceeded again the

next cycle, the control will again attempt another

freeze cycle. If the freeze cycle exceeds the maximum

time in 3 consecutive cycles, the controller will shut

the machine off and it must be manually reset.

Min freeze time – 6 minutes

If the controller switches the machine into harvest

within 20 seconds of the minimum freeze time, the

controller will harvest for a preset time and does not

stop if the curtain switch opens. If this occurs again in

the next three cycles, the machine will shut down and

must be manually reset.

Max harvest time – 3.5 minutes

If the harvest cycle has continued for 3.5 minutes

without the curtain opening, the controller will shut the

machine off for 50 minutes and then restart. If there

is another the machine will shut the machine off for

another 50 minutes and then restart. If it fails a third

consecutive time the controller will shut the machine

down and must be manually reset.
• Time between resets – 50 minutes
• Number of automatic resets – 2
• Max water fill time – 5 minutes. Machine will

attempt a restart every 20 minutes.

• Max discharge temp – 250 degrees F.
• Time interval between cleanings – 6 months

power on time - adjustable in one month

increments, can be set at 6, 5, 4 or 3 months of

power up time.

• Manual harvest time – 3 minutes
• Pump down interval – remote only. 12 hours.
• Pump down is 30 seconds of compressor only on

time.

• Minimum compressor off time – 4 minutes
• Continuous Run Time Maximum Cycles - 25

Restarts

Power Interruption

The controller will automatically restart the ice

machine after adequate voltage has been restored.
• H blinks on code display
• Status indicator light blinks
• Reservoir is drained and refilled
• Default harvest is initiated. The curtain switch

does not have to open to terminate harvest,

harvest will continue until the default harvest time

expires. Default harvest time is 3 minutes. The

machine will then return to a normal freeze cycle.

Water Interruption

The controller will attempt to fill the reservoir every

twenty minutes until it is successful.