Operational Characteristics 1200 lb system (ECC1200/EH330)
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
70/70/50
90/90/70
120/110/100
Freeze
9 to 11 minutes
12 to 13 minutes
17 to 19 minutes
Harvest
1 to 1.5 minutes
1 minute
.5 to 1 minute
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
70/70/50
90/90/70
120/110/100
Suction at head, end of Freeze 29 to 31 PSIG
28 to 32 PSIG
36 to 38 PSIG
Suction at head, Harvest - Peak 92 to 98 PSIG
165 PSIG
170 PSIG
Discharge at Condensing Unit:
Freeze - 5 minutes in
230 to 250 PSIG
250 to 285 PSIG
350 PSIG
Operational Characteristics 1400 lb system (ECC1410/EH430)
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
70/70/50
90/90/70
120/110/100
Freeze
14 minutes
16 to 17 minutes
25 to 27 minutes
Harvest
1.5 minutes
1 to 1.5 minutes
.5 to 1 minute
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
70/70/50
90/90/70
120/110/100
Suction at head, end of Freeze 35 to 37 PSIG
35 PSIG
41 to 44 PSIG
Suction at head, Harvest - Peak 85 to 105 PSIG
100 to 120 PSIG
120 to 130 PSIG
Discharge at Condensing Unit:
Freeze - 5 minutes in
220 to 230 PSIG
260 to 270 PSIG
350 to 380 PSIG
Below information applies to both size systems:
Headmaster maintains a minimum discharge pressure during freeze of 217 PSIG + 25, -15 PSIG.
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at the compressor. Maximum only occurs during harvest.
Refrigerant Charge
• 1200 - 224 oz.; 1400 - 224 oz,
Compressor Amps 1200
• Single Phase - 10 to 14
Compressor Amps, 1400
• Single Phase - 8 to 12
• Three Phase - 6 to 10
Batch Weight: 1200 - 10 lb
Batch Weight - 1400 - 14 -15 lb
Discharge Pressure Cut Out Switch
• Cuts Out at: 450 PSIG Resets at: 350 PSIG
- Prodigy Plus D Series
- C1030
- Prodigy Plus D Series Remote Condenser Modular Cuber
- Prodigy Plus D Series Remote Condenser Modular Cuber
- N1322
- N1322
- DC33
- DC33
- C2148W
- C1848
- C2148R
- C2148R
- CU3030
- CU3030
- CU3030
- EH430 D
- EH430 D
- N1322
- N1322
- N1322L
- AFE424
- AFE400
- AFE400
- C2648R
- CU0920
- CU0920
- CB1030
- CU3030
- CU50
- SCCP50
- SCCP50
- FME804 Installation
- FME804 Installation
- FME804 Installation
- NB1322
- HD30
- HD30
- HID540 Service Manual
- HID540 Service Manual
- HID540AW
- MDT4F12
- SCCP30
- SCCP30
- SCN60
- SCN60
- SCN60
- SCN60
- TDE650
- MDT5N40
- TDE650
- SCR33
- SCR33
- ECC1800
- SCCP50
- SCCP50
- SCV32
- SCV32
- 2000 Prodigy Eclipse
- 2000 Prodigy Eclipse
- 2000 Prodigy Eclipse
- EH222 with ECC
- Nugget Ice Machines
- CME650
- CME650
- CME650
- CME650
- CD200
- CME456
- CME1656
- CME456
- C2648
- CME1656R
- CME1656R
- CME1656R
- CME2006R
- CME2006R
- CME1402
- MCM1462R
- CMS1202R
- CME650R
- MCM1462R
- MCM1462R
- CME806R AutoIQ
- CME1000A
- 1000 Eclipse
- CME1002W
- CME806 AutoIQ
- CMS1002R
- MCM1062R
- MCM1062R
- MCM1462
- MCM1462
- MCM1462
- CS60
- CS55
- CS0415
- CSWE1
- CSE60
- CSW45
- TDE470
- FDE474
- TDE470
- NS650
- NSE650
- FME800
- NM1852
- NM1852
- NS650
- NM1852
- NS650
- NM1852
- FME800
- NM1852
- NS650
- NME1250
- NS650
- NSE650
- NS650
- NME650R
- NME650R
- FME804R
- NM952R
- NME650R
- FME2404
- NME650R
- NME650R
- FME2400R
- NME650R
- NME650R
- FME2404
- NM952R
- NM952R
- NME650R
- FME1504R
- NME650R
- FME804R
- NME650R
- FM24RLM
- FM24RLM
- FM24RLM
- FM24RLM
- FM24RLM
- FM24RLM
- FME1204
- FME2404R
- FME24RLM
- SLD150
- SLD150
- HD156
- IS150
- HD356
- IS220
- MAR2000
- MDT2
- NDE754
- NDE754
- MFE400
- MDT4F
- NDE750
- NDE750
- NDE750
- NDE750
- NDE750
- N1322L Service Manual
- NSE654
- NSE654
- RFE33
- RS150
- RS220
- SCE275
- SCE170
- SLE400
- SLE400
- SLE400
- SLE400