SPECIFICATIONS

71

11

SPECIFICATIONS

11.1

Pump head

11.1.1 Performance

Description

Bredel 265

Bredel 280

Bredel 2100

Max. capacity, continuous [m

3

/h]

40.0

56.0

72.0

Max. capacity, intermittent [m

3

/h]

*

*

Intermittent duty: Let the pump stand still to cool down for at least 1 hour after 2 hours of
operation.

64.4

78.2

108.0

Capacity per revolution [l/rev]

13.4

23.4

40.0

Max. permissible working pressure [kPa]

1600

Permissible ambient temperature [°C]

-20 to +45

Permissible product temperature [°C]

-10 to +80

Sound level on 1 m [dB(A)]

70