l Use a 13mm spanner to remove the bolts, washers and spacers securing the
baseplate. See 13.1 Changing pump orientation.
l Check that the O-rings (arrowed) are in place on the bent outlet. Fit the bent
outlet connection piece and the bent outlet through the bottom hole in the
bearing housing in the same way.
l Refit the baseplate.
l Fill the system with flushing fluid to the level of the top bend of the bent outlet.
Removing the static flushing device
Note: The flushing device (if fitted) must be emptied and removed before
dismantling the pump.
l To remove the static flushing device, pour the flushing fluid from the sight
glass, and reverse the sequence of operations described above.
Note: Nipples may be fitted in place of the static flushing device if desired. Use a
6mm Allen key to tighten them.
l Use a 17mm spanner to tighten it.
The bent outlet connection piece
The bent outlet