Output Structure of Parameter Lists

Line 1

Each parameter output starts with the starting character < * > ( HEX: 0x2A)

* <CR> <LF>
3 characters

Line 2

Output of model designation

N D - 7 6 0 <CR> <LF>
13 characters

2 characters

Type of display unit

End

Subsequent lines for the individual parameters:

a: Parameters:
The parameter setting can be edited by pressing the minus key (e.g. positive counting direction / negative counting direction,

etc.)

Examples:

P 0 1 I N C H = 1 <CR> <LF>
6 characters

13 characters

3 ch. 6 characters 2 characters

P 3 1 . 1 D P P O S . 5 = 5 <CR> <LF>
6 characters 13 characters 3 ch. 6 characters 2 characters

Parameter designation Parameter in plain language Sep.block Parameter value End

Left-aligned Right-aligned Right-aligned

Output

Structure

of

Parameter

Lists

Bateil2.pm6