14.5 BA

SIC R

O

T

A

TION compensation via r

o

tary axis (Cy

c

le 403,

DIN/ISO:

G403)

U

Clearance height Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999

U

Traversing to clearance height Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

U

Axis for compensation motion Q312: assignment of

the rotary axis in which the TNC is to compensate the
measured misalignment:
4: Compensate misalignment with rotary axis A
5: Compensate misalignment with rotary axis B
6: Compensate misalignment with rotary axis C

U

Set to zero after alignment Q337: Definition of

whether the TNC should set the display of the aligned
rotary axis to zero:
0: Do not reset the display of the rotary axis to 0 after
alignment
1: Reset the display of the rotary axis to 0 after
alignment

U

Number in table Q305: Enter the number in the

preset table/datum table in which the TNC is to set
the rotary axis to zero. Only effective if Q337 is set to
1. Input range 0 to 2999

U

Measured value transfer (0, 1) Q303: Specify if the

determined basic rotation is to be saved in the datum
table or in the preset table:
0: Write the measured basic rotation as a datum shift
in the active datum table. The reference system is the
active workpiece coordinate system.
1: Write the measured basic rotation into the preset
table. The reference system is the machine
coordinate system (REF system).

U

Reference angle? (0=ref. axis) Q380: Angle with

which the TNC is to align the probed straight line.
Only effective if the rotary axis C is selected
(Q312=6). Input range –360.000 to 360.000

Example: NC blocks

5 TCH PROBE 403 ROT IN C-AXIS

Q263=+0

;1ST POINT 1ST AXIS

Q264=+0

;1ST POINT 2ND AXIS

Q265=+20

;2ND POINT 1ST AXIS

Q266=+30

;2ND POINT 2ND AXIS

Q272=1

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q312=6

;COMPENSATION AXIS

Q337=0

;SET TO ZERO

Q305=1

;NO. IN TABLE

Q303=+1

;MEAS. VALUE TRANSFER

Q380=+90

;REFERENCE ANGLE