6 set basic rotation (cycle 404, din/iso: g404), Cycle run, Cycle parameters – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual
Page 302
Advertising

302
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
14.6 SET BA
SIC R
O
T
A
TION (Cy
c
le 404, DIN/ISO: G404)
14.6 SET BASIC ROTATION
(Cycle 404, DIN/ISO: G404)
Cycle run
With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.
Cycle parameters
U
Preset value for basic rotation: Angular value
at which the basic rotation is to be set. Input
range –360.000 to 360.000
U
Number in table Q305: Enter the number in the
preset table in which the TNC is to save the defined
basic rotation. Input range 0 to 2999
Example: NC blocks
5 TCH PROBE 404 BASIC ROTATION
Q307=+0
;PRESET BASIC ROTATION
Q305=1
;NO. IN TABLE
Advertising