Tool table: Tool data for 3-D touch trigger probe (only when bit 1
is set in MP7411 = 1, also see the Touch Probe Cycles Manual)
Abbr.
Input
Dialog
CAL-OF1
During calibration, the TNC stores in this column the center
misalignment in the reference axis of the 3-D probe, if a tool
number is indicated in the calibration menu.
Center misalignmt. in ref. axis?
CAL-OF2
During calibration, the TNC stores in this column the center
misalignment in the minor axis of the 3-D probe, if a tool number
is indicated in the calibration menu.
Center misalignment minor axis?
CAL-ANG
During calibration, the TNC stores in this column the spindle angle
at which the 3-D probe was calibrated, if a tool number is
indicated in the calibration menu.