HEIDENHAIN iTNC 530 (340 422) User Manual
Page 266

266
7 Programming: Miscellaneous Functions
7.
6 Miscellaneous F
unctions f
o
r Laser Cut
ting Mac
h
ines
Output voltage as a function of time (time-
dependent ramp): M203
Behavior with M203
The TNC outputs the voltage V as a function of the time TIME. The
TNC increases or decreases the current voltage linearly to the value
programmed for V within the time programmed for TIME.
Input range
Effect
M203 remains in effect until a new voltage is output through M200,
M201, M202, M203 or M204.
Output voltage as a function of time (time-
dependent pulse): M204
Behavior with M204
The TNC outputs a programmed voltage as a pulse with a
programmed duration TIME.
Input range
Effect
M204 remains in effect until a new voltage is output through M200,
M201, M202, M203 or M204.
Voltage V:
0 to 9.999 Volt
TIME:
0 to 1.999 seconds
Voltage V:
0 to 9.999 Volt
TIME:
0 to 1.999 seconds