6 communication, Communication – SMA SB 6000TL‑US Installation User Manual

Page 42

Advertising
background image

5  Electrical Connection

SMA America, LLC

42

SB6-11TL-US-IA-en-13

Installation Manual

7. Tighten all cables in the terminal blocks in the Sunny Boy with a torque of 40 in-lb. (4.5 Nm).
8. Verify that all connections are correctly cabled and tightened to the correct torque. Pull on the

cable in order to make sure that it is attached tightly enough in the terminal.

9. Close the SMA DC Disconnect as described in Section 8.4 "Closing the DC

Disconnect", page 59.

10. Close the Sunny Boy as described in Section 8.4 "Closing the DC Disconnect", page 59.

☑ The DC cables are now connected in the Sunny Boy.

5.6 Communication

The Sunny Boy can be equipped with a communication interface in order to communicate with SMA
communication products.
You will find further information and a list of applicable communication products at
www.SMA‑America.com.

4. Open the screw terminals completely by turning

them counterclockwise using a flat-head screwdriver.

5. Connect the positive DC cable to the terminal

labeled DC+ in the Sunny Boy.

6. Connect the negative DC cable to the terminal

labeled DC- in the Sunny Boy.