14-CLEANING
CLEANING OF SMOKE DUCT AND FITTING
When the product has been extracted, it is possible to operate on the left side to clean and maintain the smoke fan. To perform this
maintenance proceed as follows:
• remove the two screws “t”
• remove the plate “V1”
• remove the gasket “V2”
Always ensure this gasket is intact and if necessary, replace it.
Clean this compartment with a vacuum cleaner by inserting the nozzle on the hole near plate “V1”.
Then clean the smoke exhaust system, especially around the fittings, curves and any horizontal sections. For information on cleaning the
flue, contact a chimney sweeper.
CAUTION! The frequency with which the smoke exhaust system is cleaned depends on the use of the product and the
type of installation.
OTHER CHECKS
All gaskets fitted on components subject to maintenance (smoke extraction fan, inspection panels, etc.) must be replaced upon
maintenance. Check the tightness of the seals on the fire door.
The company recommends relying on an authorised service centre for end-of-season cleaning and maintenance, as they will carry out all
of the previously mentioned work and also a general check of the components.