43 reset, Reset -19, R. 3.3.43) when – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 55: Ar. 3.3.41, Ar. 3.3.42, R. 3.3.43

Advertising
background image

KLN 750W 032614

3-19

3.3.41

VIEW 2ND PART OF MAC ADDRESS (LAN INTERFACE ONLY)

Used to view second two hex numbers (cc.dd) of the 6-character MAC address
(aa.bb.cc.dd.ee.ff) where cc and dd are Hex numbers from 00 to FF. The default MAC address
is 70.60.42.00.00.00.

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(V.MA2).

2. Press ENTER key to view setting.

For example,

(42.00) displayed in Current display for MAC address

70.60.42.00.00.00.

3. The MAC address can be changed using SCPI commands (see Appendix B., PAR. B.41).

3.3.42

VIEW 3RD PART OF MAC ADDRESS (LAN INTERFACE ONLY)

Used to view third two hex numbers (ee.ff) of the 6-character MAC address (aa.bb.cc.dd.ee.ff)
where ee and ff are Hex numbers from 00 to FF. The default MAC address is 70.60.42.00.00.00.

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(V.MA3).

2. Press ENTER key to view setting.

For example,

(00.00) displayed in Current display for MAC address

70.60.42.00.00.00.

3. The MAC address can be changed using SCPI commands (see Appendix B., PAR. B.41).

3.3.43

RESET

The RESET function resets the value of V set and A set to 0, resets the value of OVP and OCP
to the default values (110% of rated voltage and 110% of rated current, respectively), resets
undervoltage limit to 0,and sets the output to OFF.

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(RST) to access RESET function.

2. Press ENTER key to view setting.

OFF (default) displayed as

(OFF) in Current display.

ON mode displayed as

(ON) in Current display to initiate RESET.

3. Rotate encoder until Current display shows

, then press ENTER to confirm.

Advertising