B.23 source:memory:voltage:x command, B.24 source:memory:voltage:x? query, B.25 source:voltage command – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 79: B.26 source:voltage? query, B.27 source:voltage:limit:low command, B.28 source:voltage:limit:low? query, B.23, Sour, B.24, B.25

Advertising
background image

KLN 750W 032614

B-5

B.23 SOURce:MEMory:VOLTage:X COMMAND

SOUR:MEM:VOLT:X

Syntax:

Short Form: SOUR:MEM:VOLT:X <NRf> Long Form: SOURce:MEMory:VOLTage:X <NRf>

Description:

Sets the memory location defined by X to the voltage value <NRf>.

Argument:

<NRf> is a value in the range from 0 to rated voltage of unit.

Example:

SOURce:MEMory:VOLTage:5 62.4 sets memory location 5 to 62.4V.

B.24 SOURce:MEMory:VOLTage:X?

QUERY

SOUR:MEM:VOLT:X?

Syntax:

Short Form: SOUR:MEM:VOLT:X?

Long Form: SOURce:MEMory:VOLTage:X?

Description:

Returns voltage value stored in memory location X (in volts).

Return Format: <NRf>
Example:

SOURce:MEMory:VOLTage:5? returns 6.24000E+01 (Voltage stored in memory location 5 is
62.4V).

B.25 SOURce:VOLTage COMMAND

SOUR:VOLT

Syntax:

Short Form: SOUR:VOLT <NRf>

Long Form: SOURce:VOLTage <NRf>

Description:

Sets the output voltage value. Maximum output voltage is 105% of rated voltage; minimum volt-
age is zero.

Argument:

<NRf> is a value in the range from 0 to 105% of rated voltage of unit. Rated voltage and current
are defined by model (e.g., for KLN 6-100, rated voltage is 6V, rated current is 100A).

Example:

SOURce:VOLTage 30 sets output voltage value to 30V.

B.26 SOURce:VOLTage?

QUERY

SOUR:VOLT?

Syntax:

Short Form: SOUR:VOLT?

Long Form: SOURce:VOLTage?

Description:

Indicates programmed output voltage (in volts).

Return Format: <NRf>
Example:

SOURce:VOLTage? returns 3.00000E+01 to indicate output voltage is programmed to 30V.

B.27 SOURce:VOLTage:LIMit:LOW COMMAND

SOUR:VOLT:LIM:LOW

Syntax:

Short Form: SOUR:VOLT:LIM:LOW <NRf> { MIN | MAX }
Long Form: SOURce:VOLTage:LIMit:LOW <NRf> { MIN | MAX }

Argument:

<NRf> is a value in the range from 0 to 95% of rated voltage of unit.
MIN is the minimum value for lower limit
MAX is the maximum value for lower limit

Description:

Sets the lower limit of output voltage (in volts). The lower limit can be set to a maximum of
95% of rated voltage. Minimum value for lower limit is 0. *RST sets this value to 0.

Example:

SOURce:VOLTage:LIMit:LOW 10 sets lower limit for output voltage to 10V. For a 40V model this
means that output voltage could not be programmed lower than 10V. SOURce:VOLT-
age:LIMit:LOW programs the lower limit for the 40V model 38V.

B.28 SOURce:VOLTage:LIMit:LOW?

QUERY

SOUR:VOLT:LIM:LOW?

Syntax:

Short Form: SOUR:VOLT:LIM:LOW?

Long Form: SOURce:VOLTage:LIMit:LOW?

Description:

Indicates programmed lower limit for output voltage (in volts).

Return Format: <NRf>
Example:

SOURce:VOLTage:LIMit:LOW? returns 1.00000E+01 to indicate lower limit for output voltage is
programmed to 10V.

Advertising