4.6.2 Get Live List Message Structure

Parameter Description

Command Initiator

Application

Command Name

FB_APPL_GET_LIVE_LIST

Command Number

0018h

Fragmented No

Extended Header Data

Fault information may be returned in the header of the response.

Command and Response Layout: Get Live List

Command

Response

Message ID

(ID)

(ID)

Acyclic Message Status

Word

4002h

0002h

Command

0018h

0018h

Get Live List

Data size

0000h

007Fh

127 Bytes of Data

Frame count

0001h

0001h

Frame number

0001h

0001h

Offset high

0000h

0000h

Offset low

0000h

0000h

Extended word 1

-

-

Extended word 2

-

-

Extended word 3

-

-

Extended word 4

-

-

Extended word 5

-

-

Extended word 6

-

-

Extended word 7

-

Return Code

Extended word 8

-

Fault Information

Message Data byte 1

Station Type 0

Response Data Byte 1

Message Data byte 2

Station Type 1

Response Data Byte 2

Message Data byte 3

Station Type 2

Response Data Byte 3

...

... ...

Message Data byte "n"

Station Type 126

Response Data Byte 127

Acyclic Message Status Word

Refer to Acyclic Message Status Word (page 218).

Station Type [0 … 126]

00h: Slave Station

01h: Master Station not yet ready for Token ring (station only physically at the
bus)