Procedures 5204SE-MNET-PDPMV1

♦ ProLinx Gateway

User Manual

Modbus TCP/IP to PROFIBUS DP-V1 Pass-Through Master


ProSoft Technology, Inc.

Page 73 of 235

December 22, 2009

5 Now, look for and expand the variable,

MNETDPV1_BASICVAR. From there,

look for and expand the sub-variable, M

ODULE

S

TATUS

.

Expand the O

UT

sub-

variable.

Force a one (1) into the sub-variable, GetModuleStatus. Notice that the

M

ODIFICATION

button must be engaged and you must use the

S

ET TO

1

icon option to actually have the variable value changed so the update request
will be sent.

6 Scroll within MNETDPV1_StatIn. Notice that whenever you force the

G

ET

M

ODULE

S

TATUS

update, the numbers in the Value

column for items such

as ModuleStatus_ModuleProgramScanCounter are updated.