B

KLN 94

Rev. 4, Jan/2003 10599I04.CDL

Page A-16

w

(cont)

ddsiiiiilllLLLLmm

17

s=1 active segment follows (for other magenta
segments )
d=0 solid line; d=1 dashed line
a=1 active wpt
l=1 last waypoint
x=unused

iiiii=identifier (ASCII characters); a value of 7F
hex in first byte indicates unknown ident,
remaining bytes should be ignored.
lll=waypoint latitude; packed, unsigned binary
values:

76543210 76543210 76543210
sddddddd xxmmmmmm xhhhhhhh
s=sign: 0 for north, 1 for south
ddddddd=degrees
x=unused
mmmmmm=minutes
hhhhhhh=hundredths of minutes
A value of 7F hex in the first byte indicates
that latitude and longitude are unknown, and
remaining bytes should be ignored.

LLLL=waypoint longitude; packed, unsigned
binary values:
76543210 76543210 76543210 76543210
sxxxxxxx dddddddd xxmmmmmm xhhhhhhh
s= sign: 0=East 1=West, x=unused, d=degrees,
m=minutes, h=hundredth
mm=magnetic variation at waypoint

76543210 76543210
nnnnnnnn nnnnnnnn
nnnnnnnnnnnnnnnn=Magnetic variation at
waypoint
Two's complement binary in sixteenths of
degrees.
Easterly variation is positive.
A value of 7FH in byte 16 indicates that mag-
netic variation is not presently available and
bytes 16 and 17 should be ignored.

ENHANCED RS232