Honeywell BENDIX/KING KLN 94 User Manual
Page 106
B
KLN 94
Rev. 4, Jan/2003 10599I04.CDL
Page A-16
w
(cont)
ddsiiiiilllLLLLmm
17
s=1 active segment follows (for other magenta
segments )
d=0 solid line; d=1 dashed line
a=1 active wpt
l=1 last waypoint
x=unused
iiiii=identifier (ASCII characters); a value of 7F
hex in first byte indicates unknown ident,
remaining bytes should be ignored.
lll=waypoint latitude; packed, unsigned binary
values:
76543210 76543210 76543210
sddddddd xxmmmmmm xhhhhhhh
s=sign: 0 for north, 1 for south
ddddddd=degrees
x=unused
mmmmmm=minutes
hhhhhhh=hundredths of minutes
A value of 7F hex in the first byte indicates
that latitude and longitude are unknown, and
remaining bytes should be ignored.
LLLL=waypoint longitude; packed, unsigned
binary values:
76543210 76543210 76543210 76543210
sxxxxxxx dddddddd xxmmmmmm xhhhhhhh
s= sign: 0=East 1=West, x=unused, d=degrees,
m=minutes, h=hundredth
mm=magnetic variation at waypoint
76543210 76543210
nnnnnnnn nnnnnnnn
nnnnnnnnnnnnnnnn=Magnetic variation at
waypoint
Two's complement binary in sixteenths of
degrees.
Easterly variation is positive.
A value of 7FH in byte 16 indicates that mag-
netic variation is not presently available and
bytes 16 and 17 should be ignored.
ENHANCED RS232
Item
Designator
Data
Format
Data Field
Width
Description