FORMAT C (108 BYTE ASCII STRING)

BYTE

DESCRIPTION / FORMAT

1-51

Same as Format B described above except that in the Units of Measure field, “I =
Imperial Gallons” is undefined.

52-54

Indicated Airspeed (IAS, knots)

ASCII-coded decimal format (least significant digit is units), LSB first.

Example:
An IAS of 298 knots would be sent as “892” (38H, 39H, 32H).

55

Indicated Airspeed Checksum

Break each decimal value into BCD representation. Using BCD arithmetic, sum the 3
BCD values and convert the lower-order BCD digit to an ASCII coded numeric digit.

56-58

True Airspeed (TAS, knots)

ASCII-coded decimal format as for IAS

59

True Airspeed Checksum

Sum for TAS bytes computed for IAS.

60-62

MACH (airspeed/speed of sound)

ASCII-coded decimal format with an implicit leading decimal point (least significant
digit is thousands).

Example:
A MACH value of .492 would be sent as “294” (32H, 39H, 34H).

63

MACH Checksum

Sum for MACH bytes computed as for IAS.

64-69

Pressure Altitude (PALT, feet)

ASCII-coded decimal format with a sign character.

Example:
A PALT of 34500 feet would be sent as “00543+” (30H, 30H, 35H, 34H, 33H, 2BH).

70

Pressure Altitude Checksum

Sum for PALT bytes, excluding the sign character.

Example:
The sum for -850 feet would be “3” (33H).