6 controller board overview, Table 1 controller board components, Controller board overview – Liebert AC4 User Manual

Page 10: Controller board components

Advertising
background image

Introduction

4

1.6

Controller Board Overview

The AC4’s controller board has connectors for four digital inputs and four digital outputs, as shown

below. The board comes complete with light emitting diodes (LEDs) to display the status of connected

devices, a serial communications port, a power connection and other features necessary to control

your operation.

Table 1

Controller board components

Item

Description

For more information, see:

A - Power On/Off

switch

Power switch for the controller board.

2.4:

Connect Power to the AC4

B - Audible horn

Provides audible notification when an alarm occurs.

N/A

C - Audible horn

jumper

Jumper to disable the audible horn (factory default is

enabled).

N/A

D - Common Alarm

connectors

The two common alarm connections are used to connect to

a secondary warning device such as a horn, light or

Building Management System (BMS). When an alarm is

present, the contacts close and the external warning device

is activated/notified. The common alarm contacts may be

configured to be reset with the Silence button/command.

3.0:

Wiring and Connections

3.3:

Connecting Common Alarm

Outputs

7.4:

Setup System - Setup Common

Alarm

E - Digital output

status LEDs

Each output has an LED to indicate its status: ON/OFF

(energized/de-energized).

1.7:

LED Indicators

F - Manual Override

Switch (outputs)

Placing the switch in the ON position will turn ON, or

energize, all four outputs simultaneously. This switch

removes all automatic output control from the AC4.

7.9:

Override Output

G - Digital output

connectors

Each of the four output connections is a two-state point:

ON/OFF (energized/de-energized).
An example of a field digital output is a Liebert

Environmental unit’s remote shutdown input.

3.0:

Wiring and Connections

3.2.2: Connecting Digital Outputs
5.5:

View Output Status

7.6:

Setup System - Setup Outputs

H - Status LEDs

Indicates the operational status of the controller board.

1.7:

LED Indicators

G - Digital output

connectors

J - Digital input

connectors

P - 24VAC power

connector

E - Digital output

status LEDs

I - Digital output

loss-of-power

jumper

F - Manual

Override Switch

(outputs)

H - Status LEDs

A - Power

On/Off switch

N - LCD

connector

K - Digital input

status LEDs

O - LCD

contrast

adjustment

M - DIP

switch 1

D - Common Alarm

connectors

C - Audible horn

jumper

B - Audible

horn

L - Serial interface

connector

(RS232/EIA574)