Administration – Lucent Technologies Guestworks SErver 1079984G3 User Manual

Page 35

Advertising
background image

Issue 1

April 1997

29

Feature Descriptions

Administration

0

In addition to the following, see the information about administering Recorded
Announcement equipment on Page 109 and printing reports on Page 113.

change system-parameters guestworks-bcs-options

Enter a y in the

Dual Wakeup

and

Room Activated Wakeup with

Tones

fields. These options default to y, and can be changed only by

Lucent Technologies personnel.

NOTE:

If Wakeup Activation via Tones is enabled, the speech synthe-
sizer circuit pack (TN725B) is disabled from service. This means
that guests cannot enter their own Do Not Disturb requests.

change feature-access-codes

Use this form to add the Automatic Wakeup feature access code.

change system-parameters hospitality

On Page 2 of this form, enter the time of day when you want to print the
wakeup activity report in the

Time of Scheduled Wakeup Activity

Report

field. This report is printed on the Journal/Schedule printer and

summarizes the wakeup activity for each extension that had wakeup
activity for the past 24 hours.

On Page 2 of this form, enter the time of day when you want to print the
wakeup summary report in the

Time of Scheduled Wakeup Sum-

mary Report

field. This report is printed on the Journal/Schedule

printer and gives an hour-by-hour summary of the number of scheduled
wakeup calls and a list of extensions to which wakeup calls were
attempted but did not complete during the hour.