Theory of operation – Lincoln Electric IDEALARC SVM 122-A User Manual

Page 42

Advertising
background image

OUTPUT MODE AND CONTROL,
RECTIFICATION AND FEEDBACK

The three-phase AC output from the main transformer
secondary is rectified and controlled through the SCR/
diode bridge. Output current and voltage is sensed at
the shunt and output terminals. This feedback infor-
mation is processed in the control board. The control
board compares the commands of the Mode Switch,
the Arc Force Control (constant current mode only),
and the Output Control (or remote control) with the
feedback information and sends the appropriate gate
firing signals to the SCR/diode bridge.

A “dry closure” of leads #2 and #4, either at the termi-
nal strip or the 14 pin amphenol, signals the control
board to apply gate firing signals to the SCR/ Diode
Bridge, which creates a DC voltage at the output of the
bridge assembly. If the Mode Switch is in the constant
voltage (FCAW/GMAW) mode, this DC voltage is fil-
tered by the Output Capacitors.

The heavy current carrying portion of the Mode
Switch is connected between the output choke,
which stores energy and provides current filtering,
and the negative output terminal. Depending upon
the mode selected, different portions of the choke are
needed. In the constant current mode (CC), the
entire choke is connected into the welding output cir-
cuit. When constant voltage (CV) is required, only
part of the choke is utilized.

The starting circuit board function is to momentarily
change the inductance effect that the choke has on
the welding circuit. This is accomplished by changing
the amount of “pinch” or arc control windings that are
active in the output choke. When weld current is
established, the reed switch closes and the start board
becomes inactive.

THEORY OF OPERATION

E-3

E-3

LINCOLN

®

ELECTRIC

IDEALARC DC-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

FIGURE E.3 – OUTPUT MODE AND CONTROL, RECTIFICATION AND FEEDBACK

FAN

115VAC

42VAC

14 PIN

AMPHENOL

REMOTE

CONTROL

TO

CONTROL

BOARD

CONTROL BOARD

OUTPUT

CONTROL

ARC FORCE

CONTROL

CONTROL

TRANSFORMER

POWER

SWITCH

R
E
C
O
N
N
E
C
T

INPUT

CONTACTOR

T
E
R
M

I

N

A

L

S
T
R

I

P

TRANSFORMER

MAIN

SCR

DIODE

HYBRID BRIDGE

/

PART

OF

MODE

SWITCH

CAPACITORS

SHUNT

REED

SWITCH

START

BOARD

PART

OF

MODE

SWITCH

OUTPUT

CHOKE

NEGATIVE

OUTPUT

TERMINAL

POSITIVE

OUTPUT

TERMINAL

PART OF

MODE

SWITCH

OUTPUT

G

A
T
E

S

I

G

N

A
L

S

FEEDBACK

F
E
E
D
B
A
C
K