TROUBLESHOOTING & REPAIR

F-16

F-16

LINCOLN

®

ELECTRIC

IDEALARC DC-400

INPUT CONTACTOR TEST (continued)

TEST PROCEDURE

1. Disconnect the main input supply power to

the machine.

2. With the 5/16” nut driver, remove the case

top and the reconnect panel cover.

3. Locate the two leads connected to the input

contactor coil, #233 and X1 #232 (top). See
Figure F.1 for location.

4. Connect an AC voltmeter to the leads.

Electric Shock can kill.

• With the input power on,

there are high voltages
inside the machine. Do
not reach into the
machine or touch any
internal part of the
machine while the
power is on.

5. Apply the correct voltage to the machine

and turn the power switch (S1) ON.

6. Check for 120VAC at the contactor coil

leads.

If the 120VAC is NOT present, with the
power switch (S1) on, check the power
switch (S1) and associated circuitry. See the
Wiring Diagram. Also perform the Control
Transformer (T2) Voltage Test.

If the 120VAC is present and the contactor
does NOT activate, then the input contactor
is faulty. Replace the input contactor.

WARNING

FIGURE F.1 – INPUT CONTACTOR CONNECTIONS