TROUBLESHOOTING & REPAIR

F-5

F-5

LINCOLN

®

ELECTRIC

IDEALARC DC-400

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The machine is dead – no output –
no fan – the pilot light is lit.

1. Check the three-phase input

voltage at the machine. Input
voltage must match the rating
plate and the reconnect panel.

2. Check for blown or missing

fuses in the input lines.

1. Perform the Input Contactor

Test.

2. Check the associated leads, for

loose or faulty connections,
between the input contactor
(CR1), the reconnect panel and
the main transformer. See
Wiring Diagram.

3. Perform the Main Transformer

Test.