Model 500 only – Lifebreath 500ERV User Manual

Page 22

Advertising
background image

22

To select mode of operation for ControlAir 15

Model 500 Only

Press and hold the fan selection button on the Control Pad. After 5 seconds the control will
begin to cycle each mode holding each for 2 seconds. Release the button when the desired
mode of operation is reached.

Modes of Operation

LED Indication

OFF

No LED’s illuminated

HRV/ERV is off, no controls will

initiate operation.

Standby / On

Steady Green LED and Yellow LED to indicate speed

HRV/ERV will run at speed selected in ventilation mode.
Standby mode is indicated by no speed indicator
illuminated. Optional remote controls will override standby
or selected speed into high speed.

20 On / 40 Off

Flashing Green LED and Yellow LED to indicate speed

HRV/ERV will operate in ventilation mode at speed selected
for 20 minutes and OFF for 40 minutes.

To select speed

Momentarily press fan selection button and release. HRV/ERV will move into next speed.
OFF is indicated by no yellow LED illuminated. Speed 1 is the first yellow LED. Speed five is
indicated by a flashing speed 4 LED.

Automatic Defrost

During cold outdoor conditions the HRV/ERV will occasionally go into an automatic defrost
function, which will prevent ice from forming on the core. Defrost is indicated by a flashing Red
LED indicator.