Diagnostics: device test, Trace route test results – VBrick Systems VBRICK APPLIANCE VB6000 User Manual
Page 125
Diagnostics
VBrick WM Appliance Admin Guide
115
Trace Route Test Results
The results of the test appear at the top of the screen. The results include the Resolved IP
Address of the Destination Host Name. When the test is finished or stopped, the Overall
Result will display the result of the test, such as "Test Done," or "Max hops (=30) Finished,"
or "Test Stopped," etc. An entry shows the hop number, which is equal to the TTL, IP
address (and Host Name if available) of the gateway, and round trip time of each probe. If the
probe answers are received from different gateways, the address of each responding system
will be shown. If there is no response within a 5 second timeout interval, a "*" is printed for
that probe. If the result string exceeds 255 characters, the string will be terminated by ending
it with "Too Long."
Diagnostics: Device Test
The WM Appliance automatically performs a full POST (Power On Self Test) hardware test
at power-on or reset. The results are shown on this page.
T
To run the Device Test:
1. Go to
Configuration: System > General
.
2. Set the
Configured Operational Mode
to
Diagnostics
. (After you press
Apply
, the
appliance will reboot. Wait until the front panel displays "Diagnostic Mode.")
3. Go to
Diagnostic: Device Test
and click
Begin Edit
.
4. Set test parameters (see below).
5. Click
Start
, then wait a few seconds and click
Refresh
to see the test results.
Probe Count
Can be set from 3 to 20. The default setting is 3. This setting is the
number of probe packets sent to a host at each hop.