SETUP

DRO 200E

17

Setup

The

S

key lets you access the many readout configuration parameters. Some of these

parameters are “job related”, meaning that they may change from job to job. Others are
“machine related” and are only set when the readout is installed or maintained.

Press the

S

key to access these parameters. Use the

X

key to move from one para-

meter to the next. After the last parameter, the

X

key ends the setup process and

saves any changes. Use the

C

key to return to a previous parameter. Some parameters

have several possible selections. A flashing dash by the

Y

key indicates that the

Y

key can be used to cycle through the available choices. At any time during setup, press-
ing the

S

key will end the setup process, and save changes.

“Job Related” Setup Parameters

These parameters are used to adjust the readout display to suit specific job require-
ments. You can access the job parameters by pressing the

S

key. Then press the

X

or

E

key. Use the

X

key to advance to the next parameter. Use the

C

key to

return to a previous parameter. A flashing dash next to an axis key indicates that the
key has a function.

Display Resolution

The display resolution parameter allows you to adjust the increment by which the
display counts for each axis. Press the

X

key to advance to the next parameter.

Press the

Y

key to change the numeric value of the parameter:

“X DISP” indicates the display resolution for the X-axis.
“Y DISP” indicates the display resolution for the Y-axis.
“Z DISP” indicates the display resolution for the Z-axis.

Press the

X

key to continue with Setup or the

S

key to save changes and exit Setup.

Scale Factor

This function allows the operator to adjust the display to automatically compensate
for material shrinkage or expansion so you can quickly and easily finish a job with
out the need to calculate each dimension. If the print has a shrinkage/expansion fac-
tor you can enter this value here and proceed to machine to nominal dimensions.
Press the

X

key to advance to the next parameter. Use the keypad to change the

display value.

“X FACTOR” indicates the scale factor for the X-axis.
“Y FACTOR” indicates the scale factor for the Y-axis.
“Z FACTOR” indicates the scale factor for the Z-axis.

When power is turned off or power is interrupted scale factors will return to 1.000.
Press the

X

key to continue with Setup or the

S

key to save changes and exit

Setup.