SETUP

DRO 200E

20

3.

When prompted, use the keypad to enter the actual length of the stan-

dard and press

E

. “X LEC 1” and the “LEC” value are displayed.

You can press the

Y

key to repeat this process for the same segment to

verify if the error is repeatable.

4.

Press the

X

key to begin the next segment or, if all segments are com-

plete, to advance to the next axis.

Repeat this procedure for each segment of each axis.

(

S - M

M

LEC =

)

x 1,000,000

S = Standard

length

M = Measured

length

Formula

Example

If the length of the standard you used is
10” and the measured length along the X-
axis is 9.995”, then the LEC for the X-
axis is 500 parts per million (PPM).

(

10 - 9.995

9.995

LEC =

)

x 1,000,000

LEC =

500 PPM
(rounded to the nearest
whole number)

8.1250

Opposite sides

1.

Move to the first side of the
standard and press

E

.

2.

When prompted, move to the
second side of the standard
and press

E

.

8.0000

Same side

ENTER

ENTER

To calculate linear error compensation use this formula: