Velleman HAA2801 User Manual

Page 33

Advertising
background image

CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1, 2 AND 3 (Locations 51, 52 & 53)

The three relay outputs of this keypad are programmable for Start/Stop or Timing modes. Apart from

the door access control, alarm arm-disarm control, they are also

universal timers for automatic

operators in industry with their 99,999 seconds (over 24 hours) programmable timer.

OUTPUT LOCATIONS

51

-- Location for Output 1

52

-- Location for Output 2

53

-- Location for Output 3

OUTPUT MODE & TIMING

0

– Start /Stop Mode (Toggle)

The number 0 sets the output to the

Start / Stop mode. The output Starts when an User PIN and/

or Card is entered/read; the output

Stops when an User PIN and/or Card is entered/read again.

1

-

99999

Seconds Momentary --- (Default -- Momentary 5 Seconds)

The output can be set in

Momentary Mode with the time of 1 second to 99,999 seconds. The output

will reset automatically when the time expires OR it can be

RESET manually at anytime with the

Super User Code that operates the desired output before the end of the time.
Example : Reset Output 1 --

#

1

------------- Output 1 resets

Reset Output 2 --

#

2

------------- Output 2 resets

Reset Output 3 --

#

3

------------- Output 3 resets

PERSONAL SAFETY AND SYSTEM LOCK-OUT (Location 60)

SAFETY & LOCK-OUT OPTIONS
The Options are represented by their Mode Numbers in programming. They are described below:

1

--- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds.

-- (Default)

2

---

5

-

10

---

Example : Release the lock-out --

#

9

00

--- Disappearance of all the above lock-out securities.

SUPER USER CODE

SUPER USER CODE

SUPER USER CODE

1 to 2 Digits

LOCK-OUT MODES VALIDATION

LOCATION

60

#

SUPER USER CODE

OUTPUT MODE & TIME

VALIDATION

LOCATIONS

51

-

53

0

or

1

-

99999

#

33

MASTER

INDIVIDUAL

After 10 successive false Card/User Code trials, activates the Duress output to switch to (-)

ground.
The Duress Output can be released with any user PIN or Card in the User Group 1 or Super

User PIN.

Selection of after 5 to 10 successive Card/User Code trials, the keypad locks during

15 minutes.
The keypad can be reset to release the lock-out with the “Super User Code” in the

following way.

Advertising