8 0

Door Forced Open

Warning & Time

FUNCTION MODE / TIME:

0---OFF

1-999 Seconds

80

FUNCTION / TIME

#

Mode =

0, Door

Forced

Open

Warning

OFF

8 1

Propped-up Warning &

Time

81

FUNCTION / TIME

#

Mode = 0,

Propped-

up Warning

OFF

9 0

Egress Delay Warning &

Alarm

CODE 1 - FUNCTION MODE:

1---Momentary, No warning

2---Momentary, with warning

3---Momentary, with warning +

Alarm

4---Hold Contact, No warning

5---Hold Contact, with warning

6---Hold Contact, with warning +

Alarm

CODE 2 - DELAY TIME:

0---No Delay

1-99 Seconds

90

CODE 1

CODE 2

#

Mode = 1

Momentary,

No warning

TIME = 0

No Delay

9 1

Door Opening Alarm &

TIMER

ALARM TIME:

0---No Alarm

1-999 Seconds

91

ALARM TIME

#

Time = 0,

No Alarm

9 4

Operation Mode &

Wiegand Output

MODES OF WIEGAND OUTPUT

0---Stand Alone Keypad-Valid

Codes & Cards Only

1---Reader-All Codes & Cards

2---Master Keypad-Valid Codes

& Cards only

3---Slave Keypad-Valid Codes &

Cards only

94

WIEGAND O/P MODE

#

Mode = 0

Keypad

Mode

SYSTEM

CODES

FUNCTION

CODE ENTRY

RESULTS

0 0 0 0

Factory Set Master Code

for User to set system in

programming Mode at the first

time.

THIS IS NOT A PERMANENT

SYSTEM CODE & IT IS

CHANGED IF A NEW MASTER

CODE IS PROGRAMMED.

0000 * *

OR
NEW MASTER CODE

* *

System in Programming Mode

9 9 9 9

REFRESH CODE -- Refresh

the system and set all its

function back to default values.

9999 #

All programmed data are cleared

and back to the default values

except the Master Code

8 0 8 0

DAP CODE-- Direct access to

programming mode. Valid only

in the power-up delay period

8080 #

System in Programming Mode

0 9 9 9

USER PINs / Codes / Cards

whole group clearance Code -

Key in the Code to clear all the

users in the Location

LOCATIONS:

10--- User Group 1

20--- User Group 2

30--- User Group 3

40--- Vistor Group

41--- Duress Group 1

42--- Duress Group 2

43--- Duress Group 3

LOCATION NO.

0999

#

Whole group of users in the

selected location are cleared

* *

Exit Programming Code

**

The system back to normal

opration after programming