DM84 Installation Guide

LECTROSONICS, INC.

14

Initial Setup

The initial setup of a DM84 system is a relatively simple

three step process: connect the unit to the computer,

turn on the computer and select the appropriate control

panel, preset the input, matrix and output. This process

assumes that LecNet2™ and, if necessary, the USB

driver have been previously installed. If they have not

been installed, please refer to

Installing LecNet2™

Software and USB Driver.

1) Connect the computer system to the DM84 unit us-

ing either the BLACK DB9 to stereo mini (TRS 1/8”)

cable for RS-232 communications or the USB cable

for USB control. (Both cables are included with the

unit.)

NOTE: Only one DM84 unit at a time can be

connected to a serial port using the RS-232 cable.

Multiple units may be connected to a USB port

using a USB hub.

2) Turn the computer system on. After the boot se-

quence is complete, click

Start, then All Programs.

3) Select

LecNet2, then select the DM84 control panel

from the list.

5) If the

“Just a Reminder” dialog appears, click OK

to continue.

6) Click

Connection on the Main Menu bar, then

select the type of connection between the computer

system or external control system and the DM84

unit.

The choices are:

USB - used when the computer is connected

to the DM84 unit via the front or rear

panel USB port.

Network - One or more DM84 devices may be

made available for network connections

by connecting them to a gateway server

acting as a middleman, receiving

commands for a DM84 over a network

connection, and forwarding them to the

DM84 device connected via USB.

Extron IPL T S - One or more DM84 devices

may be made available for network

connections by connecting them to

an

Extron IPL T S ethernet control

interface. The IPL T S interface acts as

a middleman, receiving commands for a

DM84 device over a network connection,

and forwarding them to the device via an

RS232 port. To work as a gateway server

the IPL T S interface must be a member

of some local area network (LAN) or

the Internet, by means of an

Ethernet

connection.

Serial->COM1 - An RS-232 port for RS-232

communications between the DM84 and

the computer sytsem, or for connecting

the DM84 to an external control system

such as those made by Crestron

®

or

AMX

®

.

NOTE: The menu will list all serial ports detected

on the PC. However, many newer PCs have no

RS232 serial ports at all, so no serial connection

options will be listed.

Go Offline - No Connection Made, this mode

can be used for off line configuration and

is the default mode.